Technical info

Code length:            32 bits
Carrier:                39.2kHz

The code is only transmitted once, and after that a stop code is transmitted.



	     +--------------------------------+                   
Header:      |                                |                  
	     +                                +----------------+..
			    16T                       8T
			   8.8ms                     4.4ms

	     +--+      
1 is coded:  |  |      
	   ..+  +------+..
	      T   3T

	     +--+  
0 is coded:  |  |  
	   ..+  +--+..
	      T  T 
			 +--+
			 |  |
After the last bit a ( ..+  +  ) is transmitted to terminate the last bit.
			  T

	      +--------------------------------+        +--+
Stop code:    |                                |        |  |
	      +                                +--------+  +
			      16T                  4T     T
			     8.8ms                2.2ms

T = 550us

Space between transmissions: 95000us between the headers of the codes.

To use the code (not with the remote package):
GROUP * 10000h + (Code * 100h) + (Code XOR FFh)  

For more information please read the documentation.